Innovenergy_trunk/python/gui/assets/data2/1670401495

102 lines
2.2 KiB
Plaintext
Raw Normal View History

2023-02-16 12:57:06 +00:00
{
"TimeStamp": "1670401495",
"Devices": [
{
"Name": "TruConvertAc",
"Type": "Inverter",
"Frequency": 50,
"Ac": [
{
"Current": 0.86,
"Voltage": 235.10000000000002,
"Phi": 1.9390642202315367
},
{
"Current": 0.62,
"Voltage": 234.70000000000002,
"Phi": 1.8859893592356212
},
{
"Current": 0.85,
"Voltage": 240.5,
"Phi": 1.8754889808102941
}
],
"Dc": {
"Current": 0,
"Voltage": 850
},
"MainState": "Operation",
"Alarms": [
"BatteryOvervoltage",
"BatteryVoltageUnderThresholdSetting",
"AuxiliarySupplyUndervoltage"
]
},
{
"Name": "TruConvertDc",
"Type": "DcDc",
"Dc": {
"Current": -1,
"Voltage": 36.7
},
"Alarm": [
"DcLinkControlAlarm",
"MasterCommunicationAlarm",
"Rs485CommunicationAlarm1"
]
},
{
"Name": "EmuMeter",
"Type": "Grid",
"Frequency": 49.900001525878906,
"Ac": [
{
"Current": 12.00100040435791,
"Voltage": 235.1999969482422,
"Phi": 0.37638346285813823
},
{
"Current": 3.6070001125335693,
"Voltage": 234.60000610351562,
"Phi": 0.6266442075751466
},
{
"Current": 2.7760000228881836,
"Voltage": 240.60000610351562,
"Phi": 0.37638346285813823
}
]
},
{
"Name": "EmuMeter",
"Type": "AcInToAcOut",
"Frequency": 49.900001525878906,
"Ac": [
{
"Current": 12.00100040435791,
"Voltage": 235.1999969482422,
"Phi": 0.37638346285813823
},
{
"Current": 3.6070001125335693,
"Voltage": 234.60000610351562,
"Phi": 0.6266442075751466
},
{
"Current": 2.7760000228881836,
"Voltage": 240.60000610351562,
"Phi": 0.37638346285813823
}
]
},
{
"Name": "ampt",
"Type": "PvOnDc",
"Dc": {
"Current": 262.158,
"Voltage": 921.734
}
}
]
}