Innovenergy_trunk/python/gui/assets/data2/1670402393

102 lines
2.2 KiB
Plaintext
Raw Normal View History

2023-02-16 12:57:06 +00:00
{
"TimeStamp": "1670402393",
"Devices": [
{
"Name": "TruConvertAc",
"Type": "Inverter",
"Frequency": 50.02,
"Ac": [
{
"Current": 0.93,
"Voltage": 235.60000000000002,
"Phi": 1.9823131728623846
},
{
"Current": 0.73,
"Voltage": 234.5,
"Phi": 1.907099901948877
},
{
"Current": 0.61,
"Voltage": 240.3,
"Phi": 1.8441893582623698
}
],
"Dc": {
"Current": 0,
"Voltage": 850
},
"MainState": "Operation",
"Alarms": [
"BatteryOvervoltage",
"BatteryVoltageUnderThresholdSetting",
"AuxiliarySupplyUndervoltage"
]
},
{
"Name": "TruConvertDc",
"Type": "DcDc",
"Dc": {
"Current": -1,
"Voltage": 36.800000000000004
},
"Alarm": [
"DcLinkControlAlarm",
"MasterCommunicationAlarm",
"Rs485CommunicationAlarm1"
]
},
{
"Name": "EmuMeter",
"Type": "Grid",
"Frequency": 50,
"Ac": [
{
"Current": 12.211000442504883,
"Voltage": 235.89999389648438,
"Phi": 0.34816602826113313
},
{
"Current": 4.660999774932861,
"Voltage": 234.60000610351562,
"Phi": 0.5155939965749518
},
{
"Current": 7.453999996185303,
"Voltage": 239.1999969482422,
"Phi": 0.14153940572023133
}
]
},
{
"Name": "EmuMeter",
"Type": "AcInToAcOut",
"Frequency": 50,
"Ac": [
{
"Current": 12.211000442504883,
"Voltage": 235.89999389648438,
"Phi": 0.34816602826113313
},
{
"Current": 4.660999774932861,
"Voltage": 234.60000610351562,
"Phi": 0.5155939965749518
},
{
"Current": 7.453999996185303,
"Voltage": 239.1999969482422,
"Phi": 0.14153940572023133
}
]
},
{
"Name": "ampt",
"Type": "PvOnDc",
"Dc": {
"Current": 229.39000000000001,
"Voltage": 921.7650000000001
}
}
]
}