Innovenergy_trunk/python/gui/assets/data2/1670402419

102 lines
2.2 KiB
Plaintext
Raw Normal View History

2023-02-16 12:57:06 +00:00
{
"TimeStamp": "1670402419",
"Devices": [
{
"Name": "TruConvertAc",
"Type": "Inverter",
"Frequency": 50.03,
"Ac": [
{
"Current": 0.72,
"Voltage": 235.4,
"Phi": 1.9714279194962685
},
{
"Current": 0.63,
"Voltage": 235,
"Phi": 1.8545904360032246
},
{
"Current": 0.8200000000000001,
"Voltage": 239.8,
"Phi": 1.8545904360032246
}
],
"Dc": {
"Current": 0,
"Voltage": 850
},
"MainState": "Operation",
"Alarms": [
"BatteryOvervoltage",
"BatteryVoltageUnderThresholdSetting",
"AuxiliarySupplyUndervoltage"
]
},
{
"Name": "TruConvertDc",
"Type": "DcDc",
"Dc": {
"Current": -1,
"Voltage": 36.800000000000004
},
"Alarm": [
"DcLinkControlAlarm",
"MasterCommunicationAlarm",
"Rs485CommunicationAlarm1"
]
},
{
"Name": "EmuMeter",
"Type": "Grid",
"Frequency": 50,
"Ac": [
{
"Current": 12.223999977111816,
"Voltage": 235.89999389648438,
"Phi": 0.34816602826113313
},
{
"Current": 4.9019999504089355,
"Voltage": 234.1999969482422,
"Phi": 0.4949341363801287
},
{
"Current": 7.234000205993652,
"Voltage": 239.39999389648438,
"Phi": 0.14153940572023133
}
]
},
{
"Name": "EmuMeter",
"Type": "AcInToAcOut",
"Frequency": 50,
"Ac": [
{
"Current": 12.223999977111816,
"Voltage": 235.89999389648438,
"Phi": 0.34816602826113313
},
{
"Current": 4.9019999504089355,
"Voltage": 234.1999969482422,
"Phi": 0.4949341363801287
},
{
"Current": 7.234000205993652,
"Voltage": 239.39999389648438,
"Phi": 0.14153940572023133
}
]
},
{
"Name": "ampt",
"Type": "PvOnDc",
"Dc": {
"Current": 229.39000000000001,
"Voltage": 921.7650000000001
}
}
]
}