Relaxed=0,// 0 = relaxed (System keeps running even if some slaves are in error state.)
Strict=1,// 1 = strict (System shuts down as soon as one component is in error state.)
}
publicenumSymmetricAcOperationMode:UInt16
{
//Configuration AC set values for phases L1 - L3
Asymmetric=0,
Symmetric=1,
}
publicenumPowerFactorConvention:UInt16
{
Producer=0,// 0 = producer reference frame
Consumer=1,// 1 = consumer reference frame
}
publicenumSubSlavesErrorPolicy:UInt16
{
Strict=0,// (AC-DC module switches to error state if at least one submodules is in error state
Relaxed=1,// (AC-DC module switches to error state if all submodules are in error state.)
Off=2,// (If possible AC-DC module continues operation even if all submodules are in error state.
}
publicenumDcStageConfiguration:UInt16
{
Off=0,// DC module is off, power electronic circuit is deactivated, battery voltage can be measured.
Active=1,// DC module is active and the power distribution according to parameters 4303 is active.
ActiveIndependent=2,// DC module is active and operates independent from the AC module. The battery current set point from register 4500 is getting applied.