enable PV on DC to feed in

This commit is contained in:
Yinyin Liu 2024-08-29 09:22:14 +02:00
parent 2c37150839
commit b60d279157
1 changed files with 8 additions and 0 deletions

View File

@ -70,6 +70,10 @@ async def disable_BMS_Controlling_MPPT(remote_host):
command = "dbus -y com.victronenergy.solarcharger /Settings/BmsPresent SetValue %0"
return await run_remote_command(remote_host, command)
async def enable_PV_on_DC_feedin(remote_host):
command = "dbus -y com.victronenergy.settings /Settings/CGwacs/OvervoltageFeedIn SetValue %1"
return await run_remote_command(remote_host, command)
async def check_mkVersion(remote_host):
command = "dbus -y com.victronenergy.vebus.ttyS4 /Interfaces/Mk2/Version GetValue"
return await run_remote_command(remote_host, command)
@ -253,6 +257,10 @@ async def main(remote_host):
print("Node Red is set now!")
else:
sys.exit("Failed to re-enable Node Red!")
#### 13. enable PV on DC feedin #####
print("Enable PV on DC feedin!")
print(await enable_PV_on_DC_feedin(remote_host))
##################################################### Part 3 ################################################################