cee72bebe6
|
Changes to the backend/controller: Fixed timing bug in calibration charge, rebind to udp port when the endpoint changes ip
|
2024-04-30 11:43:10 +02:00 |
atef
|
2c087c4788
|
Add Interface for Relay record.
Add Amax library.
Add preprocessor use for Amax and Adam
|
2024-04-12 11:29:46 +02:00 |
Noe
|
1338a5ecf3
|
Fixed Configuration Tab on frontend.
Fixed time axis on overview tab and main-stats (battery view tab).
|
2024-04-10 16:31:59 +02:00 |
Noe
|
907bc6f32b
|
Final Update for calibration charge
|
2024-03-20 14:53:36 +01:00 |
atef
|
7b5b529080
|
reformatting must do calibration charge
|
2024-03-20 13:52:00 +01:00 |
Noe
|
67343ad842
|
Update controller functionality to support calibration charge date selection
|
2024-03-15 17:01:12 +01:00 |
Noe
|
ca3c9d2903
|
update config types in controller
|
2024-03-11 16:10:47 +01:00 |
atef
|
f77a86c4fc
|
new system log for salimax alarms added
|
2024-03-11 15:56:38 +01:00 |
atef
|
aa0f33fcc6
|
Comment the function of next day calibration.
|
2024-02-20 17:46:13 +01:00 |
atef
|
95489c1409
|
Update Battery IO Status
|
2024-02-06 15:22:24 +01:00 |
atef
|
e56cad22a9
|
Calibration next day added.
|
2024-01-19 16:56:35 +01:00 |
atef
|
0f9a4ddc4e
|
change the config to be set
|
2023-11-27 09:30:07 +01:00 |
atef
|
825a6c87bd
|
Add the new force calibration charge in the controller
|
2023-11-27 09:28:32 +01:00 |
atef
|
a59051dcc1
|
Change LedState to SalimaxAlarmState.
Create a GetSalimaxStateAlarm that return the salimax state alarm
|
2023-11-02 13:42:26 +01:00 |
atef
|
48e766bdde
|
Add acDctoDclink in status record and CreateAvg function WIP
|
2023-10-30 16:26:32 +01:00 |
atef
|
9b1dd755e2
|
Update PvonGrid and PvOnIsland type. (this is temporary) this is must be updated to AcPvstatus
|
2023-10-23 10:45:05 +02:00 |
atef
|
358b1f0ec1
|
Add System Log to the statusRecord
|
2023-10-04 15:19:41 +02:00 |
atef
|
04bfbfc8b9
|
Add Log {Led and Message} for Salimax status and alarm
|
2023-10-04 15:17:43 +02:00 |
atef
|
3b77c4a5b2
|
Added the feature of the forceCalibrationCharge in the config file.
|
2023-09-13 10:57:12 +02:00 |
atef
|
bcaab09190
|
Correct the name of the reference Dc Link Voltage
|
2023-09-07 17:24:56 +02:00 |
ig
|
3b1a553be5
|
Limit DischargePower based on nb. of batteries that are actually connected to the DC bus, not nb. of batteries that communicate
|
2023-09-06 10:20:32 +02:00 |
ig
|
7ecb6e4607
|
Introduce VoltageRms and CurrentRms and use them where appropriate
|
2023-09-01 14:52:09 +02:00 |
ig
|
7fc5f80e8c
|
make BatteryStatus nullable
|
2023-09-01 14:36:50 +02:00 |
atef
|
26422284dd
|
Change from falg to requested
|
2023-09-01 14:14:34 +02:00 |
atef
|
9bbccfd34b
|
Add a Calibration Charge Flag based on the Time Since TOC.
|
2023-09-01 10:48:44 +02:00 |
atef
|
c5cb31ac88
|
Delete a no needed display.
|
2023-08-30 13:40:53 +02:00 |
ig
|
27a4411ebf
|
make AmptStatus nullable in StatusRecord.cs
|
2023-08-25 17:16:28 +02:00 |
ig
|
664290c44b
|
reorder Topology generation code
|
2023-08-23 09:23:50 +02:00 |
atef
|
8b159a6a2c
|
Update the state number on Select Control mode function
|
2023-08-10 13:04:07 +02:00 |
atef
|
f9193f4624
|
Introduce constant (battery heating power = 200)
|
2023-08-02 11:05:26 +02:00 |
atef
|
da38aa7b83
|
rename the log to loginfo and create log debug
|
2023-06-30 10:27:14 +02:00 |
ig
|
a761e46686
|
fix bugs introduced by 'required' changes
|
2023-06-27 17:01:40 +02:00 |
ig
|
7f97ab8e14
|
make use of "required" with "init" (.net 7)
|
2023-06-27 13:14:17 +02:00 |
ig
|
f7ee9276a3
|
Add calculated powers (loads etc.), Dc Load is still broken
|
2023-06-22 10:17:06 +02:00 |
atef
|
b8b908e7f8
|
Clean up controller
|
2023-06-22 09:55:57 +02:00 |
atef
|
8feee5db43
|
Introduce ClampMin and ClampMax
|
2023-06-20 15:34:04 +02:00 |
atef
|
789780791f
|
throw exception if min is bigger than max in Clamp
|
2023-06-20 15:27:53 +02:00 |
ig
|
dcc4bfa78a
|
implement circular current prevention
|
2023-06-20 10:23:44 +02:00 |
ig
|
d88fc677b5
|
add virtual devices
|
2023-06-20 10:23:44 +02:00 |
ig
|
eeaefb0f54
|
Salimax V2
|
2023-06-20 10:23:43 +02:00 |