import QtQuick 1.1 import com.victron.velib 1.0 import "utils.js" as Utils MbPage { property string cgwacsPath: "com.victronenergy.settings/Settings/CGwacs" property string settingsPrefix: "com.victronenergy.settings" property string batteryLifePath: cgwacsPath + "/BatteryLife" // Hub4Mode property int hub4PhaseCompensation: 1 property int hub4PhaseSplit: 2 property int hub4Disabled: 3 property bool initialized: false property VBusItem lastEoc: VBusItem { bind: "com.victronenergy.settings/Settings/Controller/LastEOC" } property int previousEocValue: lastEoc.value title: qsTr("Charging Strategy") Component.onCompleted: { initialized = true } VBusItem { id: controllerState bind: "com.victronenergy.controller/State" } property bool isCalibrationActive: controllerState.value == 3 ? true : false VBusItem { id: systemType bind: "com.victronenergy.system/SystemType" } VBusItem { id: gridSetpoint bind: "com.victronenergy.settings/Settings/CGwacs/AcPowerSetPoint" } VBusItem { id: maxChargePowerItem bind: Utils.path(cgwacsPath, "/MaxChargePower") } VBusItem { id: maxDischargePowerItem bind: Utils.path(cgwacsPath, "/MaxDischargePower") } VBusItem { id: socLimitItem bind: Utils.path(batteryLifePath, "/SocLimit") } VBusItem { id: minSocLimitItem bind: Utils.path(batteryLifePath, "/MinimumSocLimit") } VBusItem { id: stateItem bind: Utils.path(batteryLifePath, "/State") } model: hub4Settings VisualItemModel { id: hub4Settings MbItemOptions { id: chargingState description: qsTr("Charging state") readonly: true bind: "com.victronenergy.controller/State" possibleValues:[ MbOption { description: qsTr("Unknown"); value: 0 }, MbOption { description: qsTr("Heating"); value: 1 }, MbOption { description: qsTr("Optimize self-consumption"); value: 2 }, MbOption { description: qsTr("Calibration charge"); value: 3 }, MbOption { description: qsTr("Hold min SOC"); value: 4 }, MbOption { description: qsTr("Charge to min SOC"); value: 5 }, MbOption { description: qsTr("Bridge grid blackout"); value: 6 }, MbOption { description: qsTr("Limit discharge power"); value: 7 }, MbOption { description: qsTr("Scheduled charge"); value: 8 }, MbOption { description: qsTr("Limit charge power"); value: 9 }, MbOption { description: qsTr("No grid meter available"); value: 10 }, MbOption { description: qsTr("No battery available"); value: 11 }, MbOption { description: qsTr("No inverter available"); value: 12 } ] } MbItemOptionsKnown { id: timeToEoc description: qsTr("Time to calibration charge") readonly: true bind: "com.victronenergy.controller/TimeToCalibrationCharge" possibleValues:[ MbOption { description: qsTr("Now"); value: "now" } ] } MbEditBoxTime { id: startTime description: qsTr("Calibration charge start time (hh:mm)") item.bind: "com.victronenergy.settings/Settings/Controller/CalibrationChargeStartTime" writeAccessLevel: User.AccessUser } MbOK { id: eoctime description: qsTr("Start calibration charge now?") writeAccessLevel: User.AccessUser value: isCalibrationActive ? qsTr("Calibration charge started") : qsTr("Press here") show: true onClicked: { console.log("Button clicked. Current controllerState: " + controllerState.value); console.log("Button clicked. Current isCalibrationAction: " + isCalibrationActive); console.log("Button clicked. Previous LastEOC: " + previousEocValue); if (controllerState.value !== 3 && controllerState.value !== 11 && !isCalibrationActive) { console.log("Starting manual calibration charge..."); previousEocValue = lastEoc.value; console.log("Previous EOC Value saved: " + previousEocValue); lastEoc.setValue(0); console.log("Set lastEoc to 0"); isCalibrationActive = true; } else if (controllerState.value === 3 && isCalibrationActive) { console.log("Stopping manual calibration charge..."); if(previousEocValue==0){ console.log("Postpone automatic calibration charge to 1 day later."); lastEoc.setValue((new Date().getTime() - 24*60*60*1000)/1000); }else{ lastEoc.setValue(previousEocValue); console.log("Reverted lastEoc to previous value: " + previousEocValue); } isCalibrationActive = false; } else { isCalibrationActive = false; } eoctime.value = isCalibrationActive ? qsTr("Calibration charge started") : qsTr("Press here"); } Connections { target: lastEoc onValueChanged: { if (lastEoc.value !== 0 && isCalibrationActive) { console.log("Calibration charge completed, resetting button to 'Press here'."); isCalibrationActive = false; previousEocValue = lastEoc.value; eoctime.value = qsTr("Press here"); } } } } MbSpinBox { description: qsTr("Grid setpoint") //show: hub4Mode.value !== hub4Disabled && stateItem.value !== batteryKeepCharged #we don't depend on hub4Mode anymore show: true userHasWriteAccess: true bind: "com.victronenergy.settings/Settings/CGwacs/AcPowerSetPoint" numOfDecimals: 0 unit: "W" stepSize: 100 } MbSpinBox { id: minSocLimit description: qsTr("Minimum SOC (unless grid fails)") userHasWriteAccess: true //show: hub4Mode.value !== hub4Disabled && stateItem.value !== batteryKeepCharged #we don't depend on hub4Mode anymore show: true bind: Utils.path(batteryLifePath, "/MinimumSocLimit") numOfDecimals: 0 unit: "%" min: 0 max: 100 stepSize: 5 } MbSwitch { id: withoutGridMeter name: qsTr("Grid meter installed") userHasWriteAccess: true enabled: true bind: Utils.path(cgwacsPath, '/RunWithoutGridMeter') //show: hub4Mode.value !== hub4Disabled #we don't depend on hub4Mode anymore show: true invertSense: true } MbSwitch { bind: Utils.path(settingsPrefix, "/Settings/SystemSetup/HasAcOutSystem") name: qsTr("Inverter AC output in use") show: withoutGridMeter.checked userHasWriteAccess: true enabled: true } /* MbSwitch { //auskommentiert for possible future use VBusItem { id: vebusPath bind: "com.victronenergy.system/VebusService" } VBusItem { id: doNotFeedInvOvervoltage bind: Utils.path(vebusPath.value, "/Hub4/DoNotFeedInOvervoltage") } name: qsTr("Feed-in excess solarcharger power") bind: Utils.path(settingsPrefix, "/Settings/CGwacs/OvervoltageFeedIn") show: hub4Mode.value !== hub4Disabled && doNotFeedInvOvervoltage.valid userHasWriteAccess: true enabled: true }*/ MbSwitch { id: maxChargePowerSwitch name: qsTr("Limit the charge power") checked: maxChargePowerItem.value >= 0 userHasWriteAccess: true enabled: true //show: hub4Mode.value !== hub4Disabled && !(maxChargeCurrentControl.valid && maxChargeCurrentControl.value) #we don't depend on hub4Mode anymore show: true onCheckedChanged: { if (checked && maxChargePowerItem.value < 0) maxChargePowerItem.setValue(1000) else if (!checked && maxChargePowerItem.value >= 0) maxChargePowerItem.setValue(-1) } } MbSpinBox { id: maxChargePower description: qsTr("Maximum charge power") userHasWriteAccess: true show: maxChargePowerSwitch.show && maxChargePowerSwitch.checked bind: Utils.path(cgwacsPath, "/MaxChargePower") numOfDecimals: 0 unit: "W" min: 0 max: 200000 stepSize: 50 } MbSwitch { id: maxInverterPowerSwitch name: qsTr("Limit the discharge power") checked: maxDischargePowerItem.value >= 0 userHasWriteAccess: true enabled: true //show: hub4Mode.value !== hub4Disabled && stateItem.value !== batteryKeepCharged #we don't depend on hub4Mode anymore show: true onCheckedChanged: { if (checked && maxDischargePowerItem.value < 0) maxDischargePowerItem.setValue(1000) else if (!checked && maxDischargePowerItem.value >= 0) maxDischargePowerItem.setValue(-1) } } MbSpinBox { id: maxDischargePower description: qsTr("Maximum discharge power") userHasWriteAccess: true show: maxInverterPowerSwitch.show && maxInverterPowerSwitch.checked bind: Utils.path(cgwacsPath, "/MaxDischargePower") numOfDecimals: 0 unit: "W" min: 0 max: 300000 stepSize: 50 } MbSwitch { name: qsTr("Fronius Zero feed-in") bind: Utils.path(cgwacsPath, "/PreventFeedback") //show: hub4Mode.value !== hub4Disabled #we don't depend on hub4Mode anymore show: true userHasWriteAccess: true } MbItemValue { VBusItem { id: pvPowerLimiterActive bind: "com.victronenergy.hub4/PvPowerLimiterActive" } description: qsTr("Fronius Zero feed-in active") //show: hub4Mode.value !== hub4Disabled && pvPowerLimiterActive.valid #we don't depend on hub4Mode anymore show: pvPowerLimiterActive.valid item.value: pvPowerLimiterActive.value === 0 ? qsTr("No") : qsTr("Yes") } // TODO, support scheduled charging MbSubMenu { id: scheduleSettings property string bindPrefix: "com.victronenergy.settings/Settings/CGwacs/BatteryLife/Schedule/Charge/" description: qsTr("Scheduled charging") //show: hub4Mode.value !== hub4Disabled #we don't depend on hub4Mode anymore show: true subpage: Component { MbPage { title: scheduleSettings.description model: VisualItemModel { ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 0 } ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 1 } ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 2 } ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 3 } ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 4 } } } } } MbSubMenu { id: deviceItem description: qsTr("Debug") show: user.accessLevel >= User.AccessService subpage: Component { PageHub4Debug { } } } } }