import QtQuick 1.1
|
|
import com.victron.velib 1.0
|
|
import "utils.js" as Utils
|
|
|
|
|
|
MbPage {
|
|
property string cgwacsPath: "com.victronenergy.settings/Settings/CGwacs"
|
|
property string settingsPrefix: "com.victronenergy.settings"
|
|
property string batteryLifePath: cgwacsPath + "/BatteryLife"
|
|
// Hub4Mode
|
|
property int hub4PhaseCompensation: 1
|
|
property int hub4PhaseSplit: 2
|
|
property int hub4Disabled: 3
|
|
|
|
property bool initialized: false
|
|
|
|
property VBusItem lastEoc: VBusItem { bind: "com.victronenergy.settings/Settings/Controller/LastEOC" }
|
|
property int previousEocValue: lastEoc.value
|
|
|
|
title: qsTr("Charging Strategy")
|
|
|
|
Component.onCompleted: {
|
|
initialized = true
|
|
}
|
|
|
|
VBusItem {
|
|
id: controllerState
|
|
bind: "com.victronenergy.controller/State"
|
|
}
|
|
|
|
property bool isCalibrationActive: controllerState.value == 3 ? true : false
|
|
|
|
VBusItem {
|
|
id: systemType
|
|
bind: "com.victronenergy.system/SystemType"
|
|
}
|
|
|
|
VBusItem {
|
|
id: gridSetpoint
|
|
bind: "com.victronenergy.settings/Settings/CGwacs/AcPowerSetPoint"
|
|
}
|
|
|
|
VBusItem {
|
|
id: maxChargePowerItem
|
|
bind: Utils.path(cgwacsPath, "/MaxChargePower")
|
|
}
|
|
|
|
VBusItem {
|
|
id: maxDischargePowerItem
|
|
bind: Utils.path(cgwacsPath, "/MaxDischargePower")
|
|
}
|
|
|
|
VBusItem {
|
|
id: socLimitItem
|
|
bind: Utils.path(batteryLifePath, "/SocLimit")
|
|
}
|
|
|
|
VBusItem {
|
|
id: minSocLimitItem
|
|
bind: Utils.path(batteryLifePath, "/MinimumSocLimit")
|
|
}
|
|
|
|
VBusItem {
|
|
id: stateItem
|
|
bind: Utils.path(batteryLifePath, "/State")
|
|
}
|
|
|
|
|
|
model: hub4Settings
|
|
|
|
VisualItemModel {
|
|
id: hub4Settings
|
|
|
|
MbItemOptions {
|
|
id: chargingState
|
|
description: qsTr("Charging state")
|
|
readonly: true
|
|
bind: "com.victronenergy.controller/State"
|
|
possibleValues:[
|
|
MbOption { description: qsTr("Unknown"); value: 0 },
|
|
MbOption { description: qsTr("Heating"); value: 1 },
|
|
MbOption { description: qsTr("Optimize self-consumption"); value: 2 },
|
|
MbOption { description: qsTr("Calibration charge"); value: 3 },
|
|
MbOption { description: qsTr("Hold min SOC"); value: 4 },
|
|
MbOption { description: qsTr("Charge to min SOC"); value: 5 },
|
|
MbOption { description: qsTr("Bridge grid blackout"); value: 6 },
|
|
MbOption { description: qsTr("Limit discharge power"); value: 7 },
|
|
MbOption { description: qsTr("Scheduled charge"); value: 8 },
|
|
MbOption { description: qsTr("Limit charge power"); value: 9 },
|
|
MbOption { description: qsTr("No grid meter available"); value: 10 },
|
|
MbOption { description: qsTr("No battery available"); value: 11 },
|
|
MbOption { description: qsTr("No inverter available"); value: 12 }
|
|
]
|
|
}
|
|
|
|
MbItemOptionsKnown {
|
|
id: timeToEoc
|
|
description: qsTr("Time to calibration charge")
|
|
readonly: true
|
|
bind: "com.victronenergy.controller/TimeToCalibrationCharge"
|
|
possibleValues:[
|
|
MbOption { description: qsTr("Now"); value: "now" }
|
|
]
|
|
}
|
|
|
|
MbEditBoxTime {
|
|
id: startTime
|
|
description: qsTr("Calibration charge start time (hh:mm)")
|
|
item.bind: "com.victronenergy.settings/Settings/Controller/CalibrationChargeStartTime"
|
|
writeAccessLevel: User.AccessUser
|
|
}
|
|
|
|
MbOK {
|
|
id: eoctime
|
|
description: qsTr("Start calibration charge now?")
|
|
writeAccessLevel: User.AccessUser
|
|
value: isCalibrationActive ? qsTr("Calibration charge started") : qsTr("Press here")
|
|
show: true
|
|
onClicked: {
|
|
console.log("Button clicked. Current controllerState: " + controllerState.value);
|
|
console.log("Button clicked. Current isCalibrationAction: " + isCalibrationActive);
|
|
console.log("Button clicked. Previous LastEOC: " + previousEocValue);
|
|
|
|
if (controllerState.value !== 3 && controllerState.value !== 11 && !isCalibrationActive) {
|
|
console.log("Starting manual calibration charge...");
|
|
previousEocValue = lastEoc.value;
|
|
console.log("Previous EOC Value saved: " + previousEocValue);
|
|
lastEoc.setValue(0);
|
|
console.log("Set lastEoc to 0");
|
|
isCalibrationActive = true;
|
|
} else if (controllerState.value === 3 && isCalibrationActive) {
|
|
console.log("Stopping manual calibration charge...");
|
|
if(previousEocValue==0){
|
|
console.log("Postpone automatic calibration charge to 1 day later.");
|
|
lastEoc.setValue((new Date().getTime() - 24*60*60*1000)/1000);
|
|
}else{
|
|
lastEoc.setValue(previousEocValue);
|
|
console.log("Reverted lastEoc to previous value: " + previousEocValue);
|
|
}
|
|
isCalibrationActive = false;
|
|
} else {
|
|
isCalibrationActive = false;
|
|
}
|
|
|
|
eoctime.value = isCalibrationActive ? qsTr("Calibration charge started") : qsTr("Press here");
|
|
}
|
|
|
|
Connections {
|
|
target: lastEoc
|
|
onValueChanged: {
|
|
if (lastEoc.value !== 0 && isCalibrationActive) {
|
|
console.log("Calibration charge completed, resetting button to 'Press here'.");
|
|
isCalibrationActive = false;
|
|
previousEocValue = lastEoc.value;
|
|
eoctime.value = qsTr("Press here");
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
MbSpinBox {
|
|
description: qsTr("Grid setpoint")
|
|
//show: hub4Mode.value !== hub4Disabled && stateItem.value !== batteryKeepCharged #we don't depend on hub4Mode anymore
|
|
show: true
|
|
userHasWriteAccess: true
|
|
bind: "com.victronenergy.settings/Settings/CGwacs/AcPowerSetPoint"
|
|
numOfDecimals: 0
|
|
unit: "W"
|
|
stepSize: 100
|
|
}
|
|
|
|
MbSpinBox {
|
|
id: minSocLimit
|
|
description: qsTr("Minimum SOC (unless grid fails)")
|
|
userHasWriteAccess: true
|
|
//show: hub4Mode.value !== hub4Disabled && stateItem.value !== batteryKeepCharged #we don't depend on hub4Mode anymore
|
|
show: true
|
|
bind: Utils.path(batteryLifePath, "/MinimumSocLimit")
|
|
numOfDecimals: 0
|
|
unit: "%"
|
|
min: 0
|
|
max: 100
|
|
stepSize: 5
|
|
}
|
|
|
|
MbSwitch {
|
|
id: withoutGridMeter
|
|
name: qsTr("Grid meter installed")
|
|
userHasWriteAccess: true
|
|
enabled: true
|
|
bind: Utils.path(cgwacsPath, '/RunWithoutGridMeter')
|
|
//show: hub4Mode.value !== hub4Disabled #we don't depend on hub4Mode anymore
|
|
show: true
|
|
invertSense: true
|
|
}
|
|
|
|
MbSwitch {
|
|
bind: Utils.path(settingsPrefix, "/Settings/SystemSetup/HasAcOutSystem")
|
|
name: qsTr("Inverter AC output in use")
|
|
show: withoutGridMeter.checked
|
|
userHasWriteAccess: true
|
|
enabled: true
|
|
}
|
|
|
|
/* MbSwitch { //auskommentiert for possible future use
|
|
VBusItem {
|
|
id: vebusPath
|
|
bind: "com.victronenergy.system/VebusService"
|
|
}
|
|
VBusItem {
|
|
id: doNotFeedInvOvervoltage
|
|
bind: Utils.path(vebusPath.value, "/Hub4/DoNotFeedInOvervoltage")
|
|
}
|
|
name: qsTr("Feed-in excess solarcharger power")
|
|
bind: Utils.path(settingsPrefix, "/Settings/CGwacs/OvervoltageFeedIn")
|
|
show: hub4Mode.value !== hub4Disabled && doNotFeedInvOvervoltage.valid
|
|
userHasWriteAccess: true
|
|
enabled: true
|
|
}*/
|
|
|
|
MbSwitch {
|
|
id: maxChargePowerSwitch
|
|
name: qsTr("Limit the charge power")
|
|
checked: maxChargePowerItem.value >= 0
|
|
userHasWriteAccess: true
|
|
enabled: true
|
|
//show: hub4Mode.value !== hub4Disabled && !(maxChargeCurrentControl.valid && maxChargeCurrentControl.value) #we don't depend on hub4Mode anymore
|
|
show: true
|
|
onCheckedChanged: {
|
|
if (checked && maxChargePowerItem.value < 0)
|
|
maxChargePowerItem.setValue(1000)
|
|
else if (!checked && maxChargePowerItem.value >= 0)
|
|
maxChargePowerItem.setValue(-1)
|
|
}
|
|
}
|
|
|
|
MbSpinBox {
|
|
id: maxChargePower
|
|
description: qsTr("Maximum charge power")
|
|
userHasWriteAccess: true
|
|
show: maxChargePowerSwitch.show && maxChargePowerSwitch.checked
|
|
bind: Utils.path(cgwacsPath, "/MaxChargePower")
|
|
numOfDecimals: 0
|
|
unit: "W"
|
|
min: 0
|
|
max: 200000
|
|
stepSize: 50
|
|
}
|
|
|
|
MbSwitch {
|
|
id: maxInverterPowerSwitch
|
|
name: qsTr("Limit the discharge power")
|
|
checked: maxDischargePowerItem.value >= 0
|
|
userHasWriteAccess: true
|
|
enabled: true
|
|
//show: hub4Mode.value !== hub4Disabled && stateItem.value !== batteryKeepCharged #we don't depend on hub4Mode anymore
|
|
show: true
|
|
onCheckedChanged: {
|
|
if (checked && maxDischargePowerItem.value < 0)
|
|
maxDischargePowerItem.setValue(1000)
|
|
else if (!checked && maxDischargePowerItem.value >= 0)
|
|
maxDischargePowerItem.setValue(-1)
|
|
}
|
|
}
|
|
|
|
MbSpinBox {
|
|
id: maxDischargePower
|
|
description: qsTr("Maximum discharge power")
|
|
userHasWriteAccess: true
|
|
show: maxInverterPowerSwitch.show && maxInverterPowerSwitch.checked
|
|
bind: Utils.path(cgwacsPath, "/MaxDischargePower")
|
|
numOfDecimals: 0
|
|
unit: "W"
|
|
min: 0
|
|
max: 300000
|
|
stepSize: 50
|
|
}
|
|
|
|
MbSwitch {
|
|
name: qsTr("Fronius Zero feed-in")
|
|
bind: Utils.path(cgwacsPath, "/PreventFeedback")
|
|
//show: hub4Mode.value !== hub4Disabled #we don't depend on hub4Mode anymore
|
|
show: true
|
|
userHasWriteAccess: true
|
|
}
|
|
|
|
MbItemValue {
|
|
VBusItem {
|
|
id: pvPowerLimiterActive
|
|
bind: "com.victronenergy.hub4/PvPowerLimiterActive"
|
|
}
|
|
description: qsTr("Fronius Zero feed-in active")
|
|
//show: hub4Mode.value !== hub4Disabled && pvPowerLimiterActive.valid #we don't depend on hub4Mode anymore
|
|
show: pvPowerLimiterActive.valid
|
|
item.value: pvPowerLimiterActive.value === 0 ? qsTr("No") : qsTr("Yes")
|
|
}
|
|
|
|
// TODO, support scheduled charging
|
|
|
|
MbSubMenu {
|
|
id: scheduleSettings
|
|
property string bindPrefix: "com.victronenergy.settings/Settings/CGwacs/BatteryLife/Schedule/Charge/"
|
|
description: qsTr("Scheduled charging")
|
|
//show: hub4Mode.value !== hub4Disabled #we don't depend on hub4Mode anymore
|
|
show: true
|
|
subpage: Component {
|
|
MbPage {
|
|
title: scheduleSettings.description
|
|
model: VisualItemModel {
|
|
ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 0 }
|
|
ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 1 }
|
|
ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 2 }
|
|
ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 3 }
|
|
ChargeScheduleItem { bindPrefix: scheduleSettings.bindPrefix; scheduleNumber: 4 }
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
MbSubMenu {
|
|
id: deviceItem
|
|
description: qsTr("Debug")
|
|
show: user.accessLevel >= User.AccessService
|
|
subpage: Component {
|
|
PageHub4Debug { }
|
|
}
|
|
}
|
|
}
|
|
}
|