/*using System.Reactive.Linq;
|
|
using InnovEnergy.Lib.Devices.IEM3kGridMeter;
|
|
using InnovEnergy.Lib.Protocols.DBus;
|
|
using InnovEnergy.Lib.Protocols.Modbus.Clients;
|
|
using InnovEnergy.Lib.Utils;
|
|
using InnovEnergy.Lib.Utils.Reflection;
|
|
using InnovEnergy.Lib.Victron.VeDBus;
|
|
|
|
namespace InnovEnergy.App.SchneiderDriver;
|
|
|
|
public static class SchneiderMeterDriver
|
|
{
|
|
public static Task<Exception> Run(String hostName, Bus dbusAddress)
|
|
{
|
|
return Run(hostName, ModbusTcpClient.DefaultPort, dbusAddress);
|
|
}
|
|
|
|
public static async Task<Exception> Run(String hostName, UInt16 port, Bus dbusAddress)
|
|
{
|
|
// var ep = new UnixDomainSocketEndPoint("/home/eef/graber_dbus.sock");
|
|
// var auth = AuthenticationMethod.ExternalAsRoot();
|
|
// dbusAddress = new Bus(ep, auth);
|
|
|
|
var schneider = new Iem3KGridMeterDevice(hostName, port, Config.ModbusNodeId);
|
|
|
|
|
|
var schneiderStatus = Observable
|
|
.Interval(Config.UpdatePeriod)
|
|
.Select(_ => schneider.Read())
|
|
.Publish();
|
|
|
|
var x = schneider.Read();
|
|
|
|
x?.ActivePowerL1.WriteLine();
|
|
x?.ActivePowerL2.WriteLine();
|
|
x?.ActivePowerL3.WriteLine();
|
|
|
|
|
|
var poller = schneiderStatus.Connect();
|
|
|
|
var properties = Config.DefaultProperties;
|
|
|
|
foreach (var p in properties)
|
|
{
|
|
p.WriteLine(" Signal");
|
|
}
|
|
|
|
// Step 1: Access Config.Signals
|
|
var signalsCollection = Config.Signals;
|
|
|
|
foreach (var s in signalsCollection)
|
|
{
|
|
s.WriteLine(" Signal");
|
|
}
|
|
|
|
var signals = Config
|
|
.Signals
|
|
.Select(signal => schneiderStatus.Select(signal.ToVeProperty))
|
|
.Merge()
|
|
.Do(p => properties.Set(p));
|
|
|
|
// TODO: remove when possible
|
|
// Apparently some VE services need to be periodically reminded that
|
|
// this service is /Connected
|
|
schneiderStatus.Subscribe(_ => properties.Set("/Connected", 1));
|
|
|
|
// Wait until status is read once to make sure all
|
|
// properties are set when we go onto the bus.
|
|
var dbus = schneiderStatus
|
|
.Skip(1)
|
|
.Take(1)
|
|
.SelectMany(_ => PublishPropertiesOnDBus(properties, dbusAddress));
|
|
|
|
return await signals
|
|
.MergeErrors(dbus)
|
|
.Finally(poller.Dispose)
|
|
.SelectErrors();
|
|
|
|
}
|
|
|
|
|
|
private static Task<Exception> PublishPropertiesOnDBus(VeProperties properties, Bus bus)
|
|
{
|
|
Console.WriteLine($"Connecting to DBus {bus}");
|
|
return properties.PublishOnDBus(bus, Config.BusName);
|
|
}
|
|
}*/
|
|
|
|
using System;
|
|
using System.Reactive.Linq;
|
|
using InnovEnergy.Lib.Devices.IEM3kGridMeter;
|
|
using InnovEnergy.Lib.Protocols.DBus;
|
|
using InnovEnergy.Lib.Protocols.Modbus.Clients;
|
|
using InnovEnergy.Lib.Utils;
|
|
using InnovEnergy.Lib.Victron.VeDBus;
|
|
|
|
namespace InnovEnergy.App.SchneiderDriver
|
|
{
|
|
public static class SchneiderMeterDriver
|
|
{
|
|
public static Task<Exception> Run(string hostName, Bus dbusAddress)
|
|
{
|
|
return Run(hostName, ModbusTcpClient.DefaultPort, dbusAddress);
|
|
}
|
|
|
|
public static async Task<Exception> Run(string hostName, ushort port, Bus dbusAddress)
|
|
{
|
|
var schneider = new Iem3KGridMeterDevice(hostName, port, Config.ModbusNodeId);
|
|
var schneiderStatus = Observable
|
|
.Interval(Config.UpdatePeriod)
|
|
.Select(_ =>
|
|
{
|
|
var status = schneider.Read();
|
|
if (status == null)
|
|
{
|
|
Console.WriteLine("Failed to read data from Iem3KGridMeterDevice");
|
|
}
|
|
return status;
|
|
})
|
|
.Where(status => status != null) // Ignore null readings
|
|
.Publish();
|
|
|
|
var poller = schneiderStatus.Connect();
|
|
var properties = Config.DefaultProperties;
|
|
|
|
var signals = Config
|
|
.Signals
|
|
.Select(signal => schneiderStatus.Select(signal.ToVeProperty))
|
|
.Merge()
|
|
.Do(p => properties.Set(p));
|
|
|
|
schneiderStatus.Subscribe(_ => properties.Set("/Connected", 1));
|
|
|
|
var dbus = schneiderStatus
|
|
.Skip(1)
|
|
.Take(1)
|
|
.SelectMany(_ => PublishPropertiesOnDBus(properties, dbusAddress));
|
|
|
|
return await signals
|
|
.MergeErrors(dbus)
|
|
.Finally(poller.Dispose)
|
|
.SelectErrors();
|
|
}
|
|
|
|
private static Task<Exception> PublishPropertiesOnDBus(VeProperties properties, Bus bus)
|
|
{
|
|
Console.WriteLine($"Connecting to DBus {bus}");
|
|
return properties.PublishOnDBus(bus, Config.BusName);
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
|
|
|