Innovenergy_trunk/NodeRed/dbus-csv-files/config.py

52 lines
999 B
Python

import serial
import logging
# dbus configuration
FIRMWARE_VERSION = 1 # value returned by getValue (getText returns string value reported by battery)
HARDWARE_VERSION = 1 # value returned by getValue (getText returns string value reported by battery)
CONNECTION = 'Modbus RTU'
PRODUCT_NAME = 'FZS 48TL200'
PRODUCT_ID = 0xB012 # assigned by victron
DEVICE_INSTANCE = 1
SERVICE_NAME_PREFIX = 'com.victronenergy.battery.'
# driver configuration
SOFTWARE_VERSION = '3.0.3'
UPDATE_INTERVAL = 2000 # milliseconds
#LOG_LEVEL = logging.INFO
LOG_LEVEL = logging.DEBUG
# modbus configuration
BASE_ADDRESS = 999
#NO_OF_REGISTERS = 63
NO_OF_REGISTERS = 64
MAX_SLAVE_ADDRESS = 10
# RS 485 configuration
PARITY = serial.PARITY_ODD
TIMEOUT = 0.1 # seconds
BAUD_RATE = 115200
BYTE_SIZE = 8
STOP_BITS = 1
MODE = 'rtu'
# battery configuration
MAX_CHARGE_VOLTAGE = 58
I_MAX_PER_STRING = 15
NUM_OF_STRING_PER_BATTERY = 5
AH_PER_STRING = 40
V_MAX = 54.2
R_STRING_MIN = 0.125
R_STRING_MAX = 0.250